Ready Mix Concrete Dispatch: (800) 834.7557
Rock and Sand Dispatch: (800) 232.3695
Guidelines
FAQs
Technical Information

GUIDELINES

Planning

Thickness
3_ to 4 inches is common for residential use.
Base
Sand or other granular material assists in providing uniformity and drainage. Never use cinders under a slab
Drainage
Always slope outside slabs for positive drainage. Make sure no water runs toward the house, unless special drains are incorporated to intercept such flow. The surface of the base should generally parallel the final slab slope. A minimum slope of slab should be 1/8 inch drop per foot.

Preparation

Excavating
Be sure to take out all organic matter – grass, leaves, tree roots, wood, etc. Compaction: Sub grade must be compacted uniformly and evenly so the slab won’t settle and won’t vary in thickness.
Forms
Stake securely. Scrape base away from forms so edges will be at least full thickness, because if edges are thinner, cracks could develop due to differential thickness. If you decide on a 3_ inch pavement, you can form it with 2x4 lumber.
Isolation
Before concrete is delivered, install pre-molded joint material wherever flatwork comes against buildings, steps, walls, existing slabs, etc. This is so new concrete won’t bond to the structures. Joint material must extend through the full depth of the slab.
Moistening
Shortly before placing concrete, wet the forms and the sub grade. Don’t over wet to create a muddy condition.
Special Features
If plastic is used directly under the slab (to prevent vapor when bonded floor coverings are used, or to help in radon control) it should be understood that all water must exit through the top of the slab and finishing operations and timing can be affected.

Specifications for Concrete

Strength
A high quality mix should be used. Water reducers, set retarders in hot weather, accelerators in cold weather and other adaptations for your particular application and circumstances should be discussed between your contractor and a representative from Robertson’s Ready Mix.
Slump and Water Content
A controlled water-cement ratio is more important than slump. A 5 to 6 inch slump is usually desired by the finisher for hand finishing. Water reducers and cementitious material contents should be used to maintain a water-to-cementitious content of 0.5 or less in all cases. For outside concrete slabs, a water-to-cementitious content of 0.45 or less is recommended.
Air
Total amount of entrained air for outside concrete slabs should be 5% to 8%. Slabs never subjected to free/thaw conditions may be constructed with air entrained or non-air entrained concrete at the contractor’s option.

Placing

Addition of Water
Water should not be added at the jobsite, unless absolutely necessary in preventing unworkable concrete. Water additions can reduce durability and strength by diluting the cement content. If water is added to the truck at the job site, such additions should be recorded on the trip ticket and the concrete should be remixed approximately 30 revolutions of the truck mixer before discharge.
Filling the Forms
Chute, wheel, or shovel the concrete directly into its final position. Don’t dump it in piles and then flow, drag or rake it the rest of the way.
Leveling
Screed (strike off) twice to level the surface. Immediately use wood or magnesium bull float to take out small high and low spots. Then, stop everything on that portion of the slab until bleed water (water sheen) disappears from the surface.

Finishing

When to Finish
Immediately after all the bleed water is gone is the proper time to (1) broom OR float surface ONCE, (2) if hand tooled, cut control joints while concrete is still plastic and (3) edge. Final Finish: A broom finish is recommended --- particularly on driveways, walks, etc. Where a smooth finish is desired (garage floors, patios, etc.) a wood hand float finish should be used.
Joints
Control joints may be hand tooled, sawed or formed by use of inserts. When grooved or sawed, joints must be cut to a depth of at least _ the thickness of the slab. Control joints should be spaced so that the dimension in either direction does not exceed spacing as indicated below:

Thickness of Slab
Longest Space Between Joints
3 inch
8 feet
4 inch
10 feet
5 inch or more
12 feet

This means that, in addition to lateral jointing, a joint must be cut down the center for the full length of a driveway that is 12’ wide and 3_ inches thick, or for one that is 16’ wide and 6” thick. Joints usually are at much shorter intervals in public sidewalks. Most common spacing is 5 feet. Local ordinances govern. Joins must be straight and continuous; not staggered or offset. When control joints are sawed, this should be done after all other finishing and curing application are complete and as soon as the concrete has hardened sufficiently to permit sawing without raveling.
Curing
Apply curing as soon after brooming and edging as it can be done without eroding the surface. See next section

Curing

Need for Curing
Curing is one of the most important steps in quality concrete construction and one of the most neglected. Effective curing is absolutely essential for surface durability. Fresh concrete must be kept warm and moist until the mixing water combines chemically with the cement (hydration). Without curing, the strength of the concrete (where it is needed the most) is basically reduced in half. A 4000 PSI mix becomes a 2000 PSI mix at the surface with no curing.
Curing in Warm Weather
Curing can be accomplished in a number of ways, but the simplest, most economical and widely used method is a liquid membrane which is sprayed on the surface of a slab as soon as possible after finishing. This curing compound should be applied at a rate not thinner than manufacturer’s recommendations. For example, the manufacturer may specify coverage of not more than 200 square feet per gallon (that’s twice as thick as you would apply most house paints).
Curing in Cold Weather
It is absolutely essential that fresh concrete be kept from freezing after placing. Usually protection up to one week is essential. To assist in curing and protection from freezing, it is desirable to cover slabs with insulated blankets or straw covered with a plastic sheet.
What Not to Use
Avoid any curing compound that lets the surface dry in a short time. Quick drying stops the hardening process, thus making a weak surface that is likely to scale.
Drying
Newly placed outdoor concrete not only needs time to cure, but it also needs time to dry in warm air. Concrete placed early enough in the season so that it has one month of temperature above 40 degrees (F) for curing and still another month for drying out before hard freezes are expected (certainly before deicers are applied) has a decided advantage over concrete that has not dried out when cold weather begins.

Tips to Owners

Safe Use of Deicers
Deicers containing salt and/or calcium chloride should, generally be safe for use on a quality concrete pavements after the first winter. Never use any deicer that contains either ammonium sulphate or ammonium nitrate. Anyone who buys a deicer under a brand name should read the label to see what it contains.
Fertilizers
Certain lawn fertilizers will chemically attack concrete. Care should be taken to avoid their contact with concrete. Pelletized fertilizers should be swept from concrete slabs before dissolving. Don’t use fertilizer for deicing purposes.
Sealers
Water repellant coatings and sealers can help prevent damage from freeze/thaw cycles and salting. They keep water from getting into the surface pores. Some of them may cause some darkening of the concrete. Newly cured concrete should have its period of air drying before being sealed. Most sealer applications are effective for about a two year period.